实验标准曲线分析
根据标准品和样本数据选择拟合模型,计算回收率与样本浓度,识别超范围结果并给出复现步骤。
完整提示词
<context>
A high R squared does not make a good standard curve. What matters is whether each standard, read back through the fitted curve, lands close to its nominal value (back-calculated recovery), and whether samples fall inside the range where that holds. Colorimetric protein assays are often close to linear only over part of their range; immunoassays are sigmoidal and usually need a four- or five-parameter logistic fit, often weighted, because variance grows with signal. Forcing a line through zero, subtracting blanks inconsistently, or fitting a line to a curve's plateau gives confident wrong answers. Samples outside the validated range are re-run at another dilution, not extrapolated, and results are multiplied back by their dilution factor.
</context>
<task>
Assay: {{assay}}
<standards>
{{standards}}
</standards>
{{#samples}}
<samples>
{{samples}}
</samples>
{{/samples}}
1. Model choice: inspect the shape of the data (blank-corrected) and choose linear over a restricted range, quadratic, 4PL or 5PL, following the kit's specified model if given. Say why, and whether weighting is advisable.
2. Fit and back-calculation: give the fitted parameters if you can compute them reliably from the data, otherwise say which tool to use and how. Back-calculate each standard and give percent recovery; flag standards outside about 80 to 120% recovery (or the lab's criterion), and replicates that disagree.
3. Working range: the lowest and highest standards that back-calculate acceptably define the quantifiable range. Explain how a lower limit of quantification would be formally set and that one plate does not establish it.
4. Sample results: interpolate each sample inside the range, multiply by its dilution factor, give the mean and replicate spread, and mark samples below or above the range with what to do (re-run at another dilution).
5. Flags: outliers, plateau compression, blank problems, too few points in the steep part of the curve.
6. How to reproduce: steps to redo the fit in a spreadsheet or analysis tool so the user can verify.
</task>
<constraints>
- Do arithmetic carefully and show it; if a fit needs iterative software (4PL, 5PL), do not pretend to precision you cannot compute. Give approximate values clearly labelled, or the method only.
- Never extrapolate beyond the range of acceptable standards.
- Do not drop a standard point just to improve the fit unless there is a documented reason; mark any exclusion.
- Keep units on every concentration.
{{> output/uncertainty}}
</constraints>
<output_format>
## Model choice
## Fit and back-calculation
| Standard | Nominal | Mean reading | Back-calculated | Recovery % |
## Working range
## Sample results
| Sample | Dilution | Interpolated | Final concentration | Note |
## Flags
## How to reproduce
</output_format>可替换内容
- {{assay}}
- {{standards}}
- {{#samples}}
- {{samples}}
- {{/samples}}
- {{> output/uncertainty}}
分类与标签
学习教育、实验数据分析、标准曲线、浓度计算、检验质量控制